Fitting detail · 20 Nov 2026
Aluminium glass railing systems: load cases, post spacing and the deflection limit
A railing is a barrier with a structural job. The glass is the infill, the posts carry the load, and the code decides which load case the system must survive.

The loads a railing must resist
A railing resists a line load applied at the handrail's height, a point load applied anywhere on the barrier, and the wind load on the glass.
Residential codes are usually lighter than public-building codes, and a system sold for both should be specified with the harsher case.
The line load is the governing case for the posts' spacing and the glass's thickness; the point load governs the infill's local strength.
A system designed only for the residential line load will fail a public-building check, and the difference shows in the post's spacing rather than in the glass.
Post spacing and the tributary width
Each post carries the load on half the span to each of its neighbours, so the load per post is the line load times the spacing.
Doubling the spacing doubles the load per post and multiplies the post's bending moment by four, which is why spacing is the most sensitive variable in the system.
The catalogue's spacing should be given with the load case it satisfies, because a 1.2 m spacing is a different claim under a residential and a public code.
A system that is at its maximum spacing has no margin for a post that is installed out of position, and the margin is what the installer needs.
Deflection, not strength, is the limit
A railing's serviceability limit is usually a deflection limit rather than a stress limit, and the glass and the handrail move together.
A post that is strong enough but flexible produces a railing that feels unsafe, and a flexible railing is a railing that fails an inspection regardless of its stress.
The deflection limit is usually expressed as a fraction of the post's height or of the span, and it should be stated in the system's data.
A system's stiffness comes from the post's section and its base connection, and the base connection is usually the weaker of the two.
The base plate and the anchor
The post's base plate transfers the moment to the slab through its anchors, and the anchors' spacing is what resists the moment.
A base plate with two anchors in line resists the moment as a couple, and the anchors' tension is the moment divided by their spacing.
The anchor's capacity in tension and in shear should be given, and the slab's thickness and strength should be checked against the anchor's pull-out.
A system installed on a slab that is too thin is a system whose base plate is adequate and whose substrate is not, and the failure is the slab's.
Glass infill and the bite
The glass infill is held in a base channel or a clamp, and the bite is the depth of glass inside the fixing.
A bite that is too shallow lets the glass rotate out under the point load; a bite that is too deep wastes glass and can foul the channel's drainage.
The bite's depth should be stated as a multiple of the glass's thickness, and the channel's gasket should be specified with it.
A toughened glass infill is the standard for a barrier, and a laminated toughened infill is the specification where the glass must stay in place after a break.
Drainage, corrosion and the coastal case
A base channel collects water unless it is drained, and standing water at the glass's edge is where the gasket and the aluminium corrode.
The channel should have a drainage path, and the specification should say whether the system is for indoor or outdoor use.
A coastal installation needs a marine-grade finish or a 316 stainless component set, because a 6063 aluminium post with a mill finish will chalk and pit.
The powder coating's thickness and its adhesion should be stated, and the coating's warranty should be separate from the structural warranty.
The handrail, the gap and the child's head
The handrail's height, its diameter and its clearance from the wall are all regulated dimensions, and they differ between jurisdictions.
The gap between the glass and the handrail, and the gap under the glass, are also regulated because a child can pass through or become trapped.
The system's datasheet should state the gaps it produces with the specified components, because a gap is a property of the assembly rather than of the glass.
A system that meets the loads but not the gaps is a system that fails the barrier's purpose, and the check is dimensional rather than structural.
What the system datasheet should carry
It should state the load cases satisfied, the maximum post spacing per case, the deflection limit, the base plate and anchor capacities, the bite depth and the glass specification.
It should also state the gaps, the drainage arrangement, the finish and the corrosion class.
Those items make the system specifyable and inspectable, and a datasheet without the load case is a datasheet that cannot be checked against a code.
A brand that supplies the load case with the spacing is a brand whose system can be approved rather than argued about.
The handrail's fixing and the load it transfers
The handrail is the line along which the load is applied, and its fixing to the posts transfers the line load into the posts' bending.
A handrail that is fixed with a single screw per post is a handrail that rotates, and the rotation reduces the system's stiffness before the post's does.
The handrail's section should be deep enough to spread the load to two posts, and its connection should be mechanical rather than adhesive.
A system's data should give the handrail's connection detail, because it is part of the load path and not a finishing item.
The inspection that follows the installation
An installed railing should be inspected for the gaps, the post's plumb, the anchor's tightness and the glass's bite.
A post that is out of plumb by a few millimetres per metre looks correct and reduces the system's capacity, because the load is no longer axial to the base plate.
The anchor's tightness should be checked with the specified torque rather than by feel, and the check should be recorded.
An inspection record that names the four items is the document a building control officer will ask for.
Three numbers for the tender
The tender needs the line load case, the maximum post spacing at that case, and the deflection limit, with the glass specification beside them.
A spacing quoted without the load case is a spacing that satisfies the supplier's own test rather than the building's code.
The deflection limit is the number that decides whether the railing feels solid, and it is the number that a stress calculation does not produce.
The base plate's anchor capacity belongs with those three, because the post's spacing is only achievable if the slab can take the moment.
A system data sheet that carries four numbers and their conditions is a system that can be approved in a week rather than argued about for a month.
Installation check in five minutes
Check the post's plumb in two directions, the anchor's torque, the glass's bite depth and the regulated gaps.
Then apply a firm hand load at the handrail's mid-span and watch the post's base; a base plate that lifts is an anchor that is not engaged.
The inspection record with those four items is the document that closes the installation.
Closing note
A railing's data sheet is a structural statement, and a spacing without a load case is a number that cannot be checked.
Publish the case, the spacing, the deflection limit and the anchor capacity, and the system can be approved from the catalogue.
The anchor's capacity belongs in the same table as the spacing, because a post that cannot be anchored cannot be spaced.
The railing whose post spacing is given with its load case is the aluminium glass railing system, and that pairing is what makes the system approvable.
What to check
- Line, point and wind load cases stated
- Maximum post spacing per load case
- Deflection limit as a fraction of height or span
- Base plate anchor spacing, tension and shear capacity
- Glass bite depth and infill specification
- Drainage path and indoor/outdoor rating
- Regulated gaps between glass, handrail and floor